(강하넷) www.kangha.net 강하넷 Welder / Welding Operator Qualification Record Welder's Name Welder's Identification No. Applicable Code ASME Sec. IX (Welding, Brazing, and Fusing Qualifications) Test Condition Used WPS during Performance Test PV-WPS-GT-03, 05 / PV-WPS-FC-04, 06 Base Material Welded A240-304 / A240-316 / SS400 Welding Process GTAW / FCAW Others ■ Manual □ Machine ■ Semi-auto □ Automatic Variables Tested Range Qualified Pipe Outside Diameter 6 (") 2-7/8 (") ~ Unlimited Base Metal Thickness 18 (mm) 36 (mm) Weld Deposit Thickness for Each Process GTAW 2 (mm) 4 (mm) FCAW 8 (mm) 16 (mm) Welding Position 6G All Backing (With / Without) Without All P-No. (Groups) P8 P1~15F, P34, P41~49 Filler Metal Spec. / F-No. / Classification A5.18, 5.20, 5.22, 5.9 / F6 / ER308, E316, ER70S, E71T Progression (Uphill / Downhill) ■ Uphill □ Downhill Welding Current Type / Polarity DCSP / DCRP Shielding Gas Ar 99.99% / CO2 99.9% No